"resourceType" : "StructureDefinition",
"id" : "sd-mii-icu-sonstige-pulsatile-druecke-generisch",
"url" : "https://gematik.de/fhir/isik/StructureDefinition/sd-mii-icu-sonstige-pulsatile-druecke-generisch",
"version" : "5.0.0-rc",
"name" : "SD_MII_ICU_Sonstige_Pulsatile_Druecke_Generisch",
"title" : "SD MII ICU Sonstige pulsatile Druecke Generisch",
"status" : "active",
"experimental" : false,
"date" : "2025-05-13",
"publisher" : "gematik GmbH",
"fhirVersion" : "4.0.1",
"kind" : "resource",
"abstract" : false,
"type" : "Observation",
"baseDefinition" : "http://hl7.org/fhir/StructureDefinition/Observation",
"derivation" : "constraint",
"differential" : {
"element" : [
{
"id" : "Observation.identifier",
"path" : "Observation.identifier",
"mustSupport" : true
},
{
"id" : "Observation.basedOn",
"path" : "Observation.basedOn",
"max" : "1"
},
{
"id" : "Observation.status",
"path" : "Observation.status",
"comment" : "Motivation MS: Observation.status ist bereits durch die Kardinalität der Basisklasse Observation erzwungen. Dieses Feld dient der Präzisierung des Status der Untersuchung",
"mustSupport" : true
},
{
"id" : "Observation.category",
"path" : "Observation.category",
"mustSupport" : true
},
{
"id" : "Observation.code",
"path" : "Observation.code",
"mustSupport" : true
},
{
"id" : "Observation.code.coding",
"path" : "Observation.code.coding",
"slicing" : {
"discriminator" : [
{
"type" : "pattern",
"path" : "$this"
}
],
"rules" : "open"
},
"min" : 2,
"mustSupport" : true
},
{
"id" : "Observation.code.coding.system",
"path" : "Observation.code.coding.system",
"min" : 1,
"mustSupport" : true
},
{
"id" : "Observation.code.coding.code",
"path" : "Observation.code.coding.code",
"min" : 1,
"mustSupport" : true
},
{
"id" : "Observation.code.coding.display",
"path" : "Observation.code.coding.display",
"mustSupport" : true
},
{
"id" : "Observation.code.coding:sct-generic",
"path" : "Observation.code.coding",
"sliceName" : "sct-generic",
"min" : 1,
"max" : "1",
"patternCoding" : {
"code" : "75367002",
"system" : "http://snomed.info/sct"
},
"mustSupport" : true
},
{
"id" : "Observation.code.coding:sct",
"path" : "Observation.code.coding",
"sliceName" : "sct",
"min" : 1,
"max" : "1",
"mustSupport" : true
},
{
"id" : "Observation.subject",
"path" : "Observation.subject",
"mustSupport" : true
},
{
"id" : "Observation.encounter",
"path" : "Observation.encounter",
"mustSupport" : true
},
{
"id" : "Observation.effective[x]",
"path" : "Observation.effective[x]",
"mustSupport" : true
},
{
"id" : "Observation.performer",
"path" : "Observation.performer",
"comment" : "Motivation MS: Dieses Feld stellt eine präzisierende Angaben zum Zweck der Qualitätsbewertung bereit",
"mustSupport" : true
},
{
"id" : "Observation.value[x]",
"path" : "Observation.value[x]",
"max" : "0",
"mustSupport" : true
},
{
"id" : "Observation.dataAbsentReason",
"path" : "Observation.dataAbsentReason",
"max" : "0",
"mustSupport" : true
},
{
"id" : "Observation.interpretation",
"path" : "Observation.interpretation",
"mustSupport" : true
},
{
"id" : "Observation.bodySite",
"path" : "Observation.bodySite",
"mustSupport" : true,
"binding" : {
"strength" : "extensible",
"valueSet" : "https://gematik.de/fhir/isik/ValueSet/vs-mii-icu-bodysite-observation-blutdruck",
"description" : "Codes describing anatomical locations. May include laterality. Subset of ValueSet for Monitoring und Vitaldaten."
}
},
{
"id" : "Observation.method",
"path" : "Observation.method",
"mustSupport" : true,
"binding" : {
"strength" : "extensible",
"valueSet" : "https://gematik.de/fhir/isik/ValueSet/vs-mii-icu-method-observation-blutdruck"
}
},
{
"id" : "Observation.method.coding",
"path" : "Observation.method.coding",
"mustSupport" : true
},
{
"id" : "Observation.method.coding.system",
"path" : "Observation.method.coding.system",
"mustSupport" : true
},
{
"id" : "Observation.method.coding.code",
"path" : "Observation.method.coding.code",
"mustSupport" : true
},
{
"id" : "Observation.device",
"path" : "Observation.device",
"mustSupport" : true
},
{
"id" : "Observation.referenceRange",
"path" : "Observation.referenceRange",
"max" : "0",
"mustSupport" : true
},
{
"id" : "Observation.component",
"path" : "Observation.component",
"slicing" : {
"discriminator" : [
{
"type" : "pattern",
"path" : "code"
}
],
"rules" : "open"
},
"mustSupport" : true
},
{
"id" : "Observation.component.code",
"path" : "Observation.component.code",
"mustSupport" : true
},
{
"id" : "Observation.component:SystolicBP",
"path" : "Observation.component",
"sliceName" : "SystolicBP",
"min" : 0,
"max" : "1",
"constraint" : [
{
"key" : "vs-de-3",
"human" : "If there is no value a data absent reason must be present",
"source" : "https://gematik.de/fhir/isik/StructureDefinition/sd-mii-icu-sonstige-pulsatile-druecke-generisch",
"severity" : "error",
"expression" : "value.exists() xor dataAbsentReason.exists()"
}
],
"mustSupport" : true
},
{
"id" : "Observation.component:SystolicBP.code",
"path" : "Observation.component.code",
"patternCodeableConcept" : {
"coding" : [
{
"code" : "8480-6",
"system" : "http://loinc.org"
}
]
}
},
{
"id" : "Observation.component:SystolicBP.code.coding",
"path" : "Observation.component.code.coding",
"slicing" : {
"discriminator" : [
{
"type" : "pattern",
"path" : "$this"
}
],
"rules" : "open"
},
"min" : 1,
"mustSupport" : true
},
{
"id" : "Observation.component:SystolicBP.code.coding:loinc",
"path" : "Observation.component.code.coding",
"sliceName" : "loinc",
"min" : 1,
"max" : "1",
"patternCoding" : {
"code" : "8480-6",
"system" : "http://loinc.org"
},
"mustSupport" : true
},
{
"id" : "Observation.component:SystolicBP.code.coding:loinc.system",
"path" : "Observation.component.code.coding.system",
"min" : 1,
"mustSupport" : true
},
{
"id" : "Observation.component:SystolicBP.code.coding:loinc.code",
"path" : "Observation.component.code.coding.code",
"min" : 1,
"mustSupport" : true
},
{
"id" : "Observation.component:SystolicBP.code.coding:loinc.display",
"path" : "Observation.component.code.coding.display",
"mustSupport" : true
},
{
"id" : "Observation.component:SystolicBP.code.coding:sct",
"path" : "Observation.component.code.coding",
"sliceName" : "sct",
"min" : 0,
"max" : "1",
"patternCoding" : {
"code" : "271649006",
"system" : "http://snomed.info/sct"
},
"mustSupport" : true
},
{
"id" : "Observation.component:SystolicBP.code.coding:sct.system",
"path" : "Observation.component.code.coding.system",
"min" : 1,
"mustSupport" : true
},
{
"id" : "Observation.component:SystolicBP.code.coding:sct.code",
"path" : "Observation.component.code.coding.code",
"min" : 1,
"mustSupport" : true
},
{
"id" : "Observation.component:SystolicBP.code.coding:sct.display",
"path" : "Observation.component.code.coding.display",
"mustSupport" : true
},
{
"id" : "Observation.component:SystolicBP.code.coding:IEEE-11073",
"path" : "Observation.component.code.coding",
"sliceName" : "IEEE-11073",
"min" : 0,
"max" : "*",
"patternCoding" : {
"system" : "urn:iso:std:iso:11073:10101"
},
"mustSupport" : true
},
{
"id" : "Observation.component:SystolicBP.code.coding:IEEE-11073.system",
"path" : "Observation.component.code.coding.system",
"min" : 1,
"mustSupport" : true
},
{
"id" : "Observation.component:SystolicBP.code.coding:IEEE-11073.code",
"path" : "Observation.component.code.coding.code",
"min" : 1,
"mustSupport" : true
},
{
"id" : "Observation.component:SystolicBP.code.coding:IEEE-11073.display",
"path" : "Observation.component.code.coding.display",
"mustSupport" : true
},
{
"id" : "Observation.component:SystolicBP.value[x]",
"path" : "Observation.component.value[x]",
"type" : [
{
"code" : "Quantity"
}
],
"patternQuantity" : {
"code" : "mm[Hg]",
"system" : "http://unitsofmeasure.org",
"unit" : "millimeter Mercury column"
},
"mustSupport" : true
},
{
"id" : "Observation.component:SystolicBP.value[x].value",
"path" : "Observation.component.value[x].value",
"min" : 1,
"mustSupport" : true
},
{
"id" : "Observation.component:SystolicBP.value[x].unit",
"path" : "Observation.component.value[x].unit",
"min" : 1,
"mustSupport" : true
},
{
"id" : "Observation.component:SystolicBP.value[x].system",
"path" : "Observation.component.value[x].system",
"min" : 1,
"mustSupport" : true
},
{
"id" : "Observation.component:SystolicBP.value[x].code",
"path" : "Observation.component.value[x].code",
"min" : 1,
"mustSupport" : true
},
{
"id" : "Observation.component:SystolicBP.dataAbsentReason",
"path" : "Observation.component.dataAbsentReason",
"mustSupport" : true
},
{
"id" : "Observation.component:DiastolicBP",
"path" : "Observation.component",
"sliceName" : "DiastolicBP",
"min" : 0,
"max" : "1",
"constraint" : [
{
"key" : "vs-de-3",
"human" : "If there is no value a data absent reason must be present",
"source" : "https://gematik.de/fhir/isik/StructureDefinition/sd-mii-icu-sonstige-pulsatile-druecke-generisch",
"severity" : "error",
"expression" : "value.exists() xor dataAbsentReason.exists()"
}
],
"mustSupport" : true
},
{
"id" : "Observation.component:DiastolicBP.code",
"path" : "Observation.component.code",
"patternCodeableConcept" : {
"coding" : [
{
"code" : "8462-4",
"system" : "http://loinc.org"
}
]
}
},
{
"id" : "Observation.component:DiastolicBP.code.coding",
"path" : "Observation.component.code.coding",
"slicing" : {
"discriminator" : [
{
"type" : "pattern",
"path" : "$this"
}
],
"rules" : "open"
},
"min" : 1,
"mustSupport" : true
},
{
"id" : "Observation.component:DiastolicBP.code.coding:loinc",
"path" : "Observation.component.code.coding",
"sliceName" : "loinc",
"min" : 1,
"max" : "1",
"patternCoding" : {
"code" : "8462-4",
"system" : "http://loinc.org"
},
"mustSupport" : true
},
{
"id" : "Observation.component:DiastolicBP.code.coding:loinc.system",
"path" : "Observation.component.code.coding.system",
"min" : 1,
"mustSupport" : true
},
{
"id" : "Observation.component:DiastolicBP.code.coding:loinc.code",
"path" : "Observation.component.code.coding.code",
"min" : 1,
"mustSupport" : true
},
{
"id" : "Observation.component:DiastolicBP.code.coding:loinc.display",
"path" : "Observation.component.code.coding.display",
"mustSupport" : true
},
{
"id" : "Observation.component:DiastolicBP.code.coding:sct",
"path" : "Observation.component.code.coding",
"sliceName" : "sct",
"min" : 0,
"max" : "1",
"patternCoding" : {
"code" : "271650006",
"system" : "http://snomed.info/sct"
},
"mustSupport" : true
},
{
"id" : "Observation.component:DiastolicBP.code.coding:sct.system",
"path" : "Observation.component.code.coding.system",
"min" : 1,
"mustSupport" : true
},
{
"id" : "Observation.component:DiastolicBP.code.coding:sct.code",
"path" : "Observation.component.code.coding.code",
"min" : 1,
"mustSupport" : true
},
{
"id" : "Observation.component:DiastolicBP.code.coding:sct.display",
"path" : "Observation.component.code.coding.display",
"mustSupport" : true
},
{
"id" : "Observation.component:DiastolicBP.code.coding:IEEE-11073",
"path" : "Observation.component.code.coding",
"sliceName" : "IEEE-11073",
"min" : 0,
"max" : "*",
"patternCoding" : {
"system" : "urn:iso:std:iso:11073:10101"
},
"mustSupport" : true
},
{
"id" : "Observation.component:DiastolicBP.code.coding:IEEE-11073.system",
"path" : "Observation.component.code.coding.system",
"min" : 1,
"mustSupport" : true
},
{
"id" : "Observation.component:DiastolicBP.code.coding:IEEE-11073.code",
"path" : "Observation.component.code.coding.code",
"min" : 1,
"mustSupport" : true
},
{
"id" : "Observation.component:DiastolicBP.code.coding:IEEE-11073.display",
"path" : "Observation.component.code.coding.display",
"mustSupport" : true
},
{
"id" : "Observation.component:DiastolicBP.value[x]",
"path" : "Observation.component.value[x]",
"type" : [
{
"code" : "Quantity"
}
],
"patternQuantity" : {
"code" : "mm[Hg]",
"system" : "http://unitsofmeasure.org",
"unit" : "millimeter Mercury column"
},
"mustSupport" : true
},
{
"id" : "Observation.component:DiastolicBP.value[x].value",
"path" : "Observation.component.value[x].value",
"min" : 1,
"mustSupport" : true
},
{
"id" : "Observation.component:DiastolicBP.value[x].unit",
"path" : "Observation.component.value[x].unit",
"min" : 1,
"mustSupport" : true
},
{
"id" : "Observation.component:DiastolicBP.value[x].system",
"path" : "Observation.component.value[x].system",
"min" : 1,
"mustSupport" : true
},
{
"id" : "Observation.component:DiastolicBP.value[x].code",
"path" : "Observation.component.value[x].code",
"min" : 1,
"mustSupport" : true
},
{
"id" : "Observation.component:DiastolicBP.dataAbsentReason",
"path" : "Observation.component.dataAbsentReason",
"mustSupport" : true
},
{
"id" : "Observation.component:meanBP",
"path" : "Observation.component",
"sliceName" : "meanBP",
"min" : 0,
"max" : "1",
"constraint" : [
{
"key" : "vs-de-3",
"human" : "If there is no value a data absent reason must be present",
"source" : "https://gematik.de/fhir/isik/StructureDefinition/sd-mii-icu-sonstige-pulsatile-druecke-generisch",
"severity" : "error",
"expression" : "value.exists() xor dataAbsentReason.exists()"
}
],
"mustSupport" : true
},
{
"id" : "Observation.component:meanBP.code",
"path" : "Observation.component.code",
"patternCodeableConcept" : {
"coding" : [
{
"code" : "8478-0",
"system" : "http://loinc.org"
}
]
}
},
{
"id" : "Observation.component:meanBP.code.coding",
"path" : "Observation.component.code.coding",
"slicing" : {
"discriminator" : [
{
"type" : "pattern",
"path" : "$this"
}
],
"rules" : "open"
},
"min" : 1,
"mustSupport" : true
},
{
"id" : "Observation.component:meanBP.code.coding:loinc",
"path" : "Observation.component.code.coding",
"sliceName" : "loinc",
"min" : 1,
"max" : "1",
"patternCoding" : {
"code" : "8478-0",
"system" : "http://loinc.org"
},
"mustSupport" : true
},
{
"id" : "Observation.component:meanBP.code.coding:loinc.system",
"path" : "Observation.component.code.coding.system",
"min" : 1,
"mustSupport" : true
},
{
"id" : "Observation.component:meanBP.code.coding:loinc.code",
"path" : "Observation.component.code.coding.code",
"min" : 1,
"mustSupport" : true
},
{
"id" : "Observation.component:meanBP.code.coding:loinc.display",
"path" : "Observation.component.code.coding.display",
"mustSupport" : true
},
{
"id" : "Observation.component:meanBP.code.coding:sct",
"path" : "Observation.component.code.coding",
"sliceName" : "sct",
"min" : 0,
"max" : "1",
"patternCoding" : {
"code" : "6797001",
"system" : "http://snomed.info/sct"
},
"mustSupport" : true
},
{
"id" : "Observation.component:meanBP.code.coding:sct.system",
"path" : "Observation.component.code.coding.system",
"min" : 1,
"mustSupport" : true
},
{
"id" : "Observation.component:meanBP.code.coding:sct.code",
"path" : "Observation.component.code.coding.code",
"min" : 1,
"mustSupport" : true
},
{
"id" : "Observation.component:meanBP.code.coding:sct.display",
"path" : "Observation.component.code.coding.display",
"mustSupport" : true
},
{
"id" : "Observation.component:meanBP.code.coding:IEEE-11073",
"path" : "Observation.component.code.coding",
"sliceName" : "IEEE-11073",
"min" : 0,
"max" : "*",
"patternCoding" : {
"system" : "urn:iso:std:iso:11073:10101"
},
"mustSupport" : true
},
{
"id" : "Observation.component:meanBP.code.coding:IEEE-11073.system",
"path" : "Observation.component.code.coding.system",
"min" : 1,
"mustSupport" : true
},
{
"id" : "Observation.component:meanBP.code.coding:IEEE-11073.code",
"path" : "Observation.component.code.coding.code",
"min" : 1,
"mustSupport" : true
},
{
"id" : "Observation.component:meanBP.code.coding:IEEE-11073.display",
"path" : "Observation.component.code.coding.display",
"mustSupport" : true
},
{
"id" : "Observation.component:meanBP.value[x]",
"path" : "Observation.component.value[x]",
"type" : [
{
"code" : "Quantity"
}
],
"patternQuantity" : {
"code" : "mm[Hg]",
"system" : "http://unitsofmeasure.org",
"unit" : "millimeter Mercury column"
},
"mustSupport" : true
},
{
"id" : "Observation.component:meanBP.value[x].value",
"path" : "Observation.component.value[x].value",
"min" : 1,
"mustSupport" : true
},
{
"id" : "Observation.component:meanBP.value[x].unit",
"path" : "Observation.component.value[x].unit",
"min" : 1,
"mustSupport" : true
},
{
"id" : "Observation.component:meanBP.value[x].system",
"path" : "Observation.component.value[x].system",
"min" : 1,
"mustSupport" : true
},
{
"id" : "Observation.component:meanBP.value[x].code",
"path" : "Observation.component.value[x].code",
"min" : 1,
"mustSupport" : true
}
]
},
"text" : {
}
}
XIG built as of ??metadata-date??. Found ??metadata-resources?? resources in ??metadata-packages?? packages.